2024-08-22Last updated
The following Mercury devices can support two OSDP readers on each of their onboard
reader ports: LP1502, LP4502, MP1502, MP4502, MR50-S3, and MR52-S3. You must enable this
capability in the Synergis™ Appliance Portal before configuring the readers in Config
Tool.
What you should know
- Support for two OSDP readers per port on Mercury LP1502, LP4502, MR50-S3, and MR52-S3
requires Security Center 5.10.4.0 or later.
- Support for two OSDP readers per port on Mercury MP1502 and MP4502 requires Security
Center 5.12.1.0 or later.
- When the Two OSDP readers per reader port option is enabled in
the Synergis Appliance Portal, and you only configure one of the OSDP readers on a door,
ensure that the configured reader is the primary reader, otherwise the door will be in
warning, even though it still works.
Procedure
-
In the Synergis Appliance Portal, enable the
Two OSDP readers per reader port option on the
Mercury controller settings page.
Note: When this option is enabled, the Smart card option configured
on the OSDP reader in Config Tool is on by default, and remains on in the background,
even if you turn off the option.
-
Restart Synergis Softwire.
-
Add two OSDP readers to the reader port of the Mercury controller:
-
From the Config Tool homepage, open
the Access control task, and click the Roles and
units view.
-
From the entity tree, select the Synergis™
unit, and click the Peripherals tab.
-
Double-click Reader 1, and configure the following
settings:
- Type of reader
- Select OSDP 2.
- Baud rate
- Select a bit rate.
- Address
- Select the address you configured for the first reader.
-
Click Save.
-
Double-click Reader 1 Out, and select the address you
configured for the second reader.
Note: Only the address needs to be configured because Reader 1 and Reader 1
Out use the same configuration, except the address.
-
Assign the readers to a door.
Example: Reader 1 and Reader 1 Out must be set on the same
door, and Reader 2 and Reader 2 Out must be set on the same door.
-
If the controller has a second reader port, you can repeat step 3 to configure
Reader 2 and Reader 2 Out on the second port.