What's new in Synergis Cloud Link 3.2.0

2024-11-18Last updated

Synergis™ Cloud Link 3.2.0 includes the following enhancements.

Automation engine enhancements

Conditions for triggering actions
To make your automation engine rules more strict, you can now add input state conditions to them. When the trigger event occurs, the automation engine checks the states of the inputs configured in the conditions, and then triggers the actions if the states match. If the input states don't correspond to the ones defined in the conditions, then the actions aren't triggered.

When you have multiple conditions, you can create groups of conditions and use the And and Or operators to organize them.

New trigger event
You can now configure automation engine rules with the Door - Cardholder authorized event, so that the automation engine makes the final access decision.

This event differs from the Door - Access granted event because the rule is run once access is authorized according to access rules, which occurs before access is actually granted. With the Door - Cardholder authorized event, the automation engine grants access and triggers the actions once all the conditions of the rule are met.

Automation engine mode
The new Automation engine mode setting determines which rule's actions are triggered when multiple rules are configured with the Door - Cardholder authorized event for the same door.

For more information, see Configuring automation engine rules and Configuring the automation engine mode.

Mercury integration enhancements

Removed Mercury controller setting
Previously, you could enable the No ACR without door setting on the Mercury controller settings page in the Synergis Appliance Portal. Starting in Synergis Cloud Link 3.2.0, this is now the default behavior and the setting is removed.

Allegion Schlage wireless lock integration enhancements

New firmware certification for Synergis Softwire
Synergis Cloud Link is now certified compatible with the following:
  • ENGAGE Gateway firmware 1.65.04
  • Control lock (model B) firmware 4.14.01
  • Control lock (legacy) firmware 3.13.0

For more information, see Supported Allegion Schlage wireless device firmware versions in Synergis Softwire 11.6.0.

Improved feedback on credential reads
The Access denied and Access denied: Unknown credential events are now reported by the following Allegion Schlage locks in Security Center:
  • NDE (legacy and model B)
  • LE (legacy and model B)
  • Control lock (legacy, model B, and model BM)
Support for automatic credential entry
You can now assign credentials to cardholders and visitors with the Automatic entry option in Security Center through doors controlled by Allegion Schlage wireless locks.

OSDP reader integration enhancements

New firmware certification
Synergis Cloud Link is now certified compatible with the following:
  • Schlage (formerly aptiQ) MT15-485 X14 firmware 29

For more information, see Supported OSDP readers in Synergis Softwire 11.6.0.