UL/ULC listing
is a UL294-listed subassembly under file BP20761. This certification has been made with the as part of Lifesafety Power's FPO series access control enclosures.
The is ULC 60839-11-1 certified and EN 60839-11-1 compliant as a Grade 4 system. This certification has been made using Genetec Security Center software and with the Synergis Cloud Link as part of Lifesafety Power's FPO enclosures.
For Genetec UL/ULC certification and EN compliance to be applicable, the must be installed in an access control enclosure of the following nomenclature:
SY-FPOxxx/yyy/zzz/H-qaaaaqaaaaeeee/V/WnC
The appliance is UL-certified as a stand-alone system. Installation of the appliance other than as a stand-alone system has not been evaluated by UL.
UL performance levels
- UL 294, Destructive Attack Level I
- UL 294, Line Security Level I
- UL 294, Endurance Level IV
- UL 294, Standby Power Level I
EN 60839-11-1 environmental class: I. All products, except for card readers, are intended to be installed indoors.
For ULC/EN 60839-11-1 Grade 4 compliance, FPO150/250 enclosures must use an SLA 40Ah backup battery and the PSU max output must be 9A @ 12VDC. For the FPO75, an SLA 20Ah backup battery must be used and the PSU max output must be 4.5A @ 12VDC.
The electronic access control system shall not prohibit the free exit granted by other emergency systems. For example, fire and environmental systems.
Wiring requirements
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), Canadian Electrical Code (CSA C22.1), local codes, and the authorities having jurisdiction.
Power supply requirements
You can supply power to the Synergis Cloud Link appliance using a third-party power supply that is installed in a separate enclosure. To comply with the UL certification provided by Genetec Inc., the power supply assembly, enclosure, and cabling must be ULC-60839-11-1 or UL294 certified with Class 2 power-limited output.