LED feedback
2022-03-03Last updated
The LEDs on the Synergis™ Cloud Link appliance provide visual feedback on system status and operation.
Group | LED name | LED color | Description |
---|---|---|---|
General | Information () | Orange: solid | Synergis Cloud Link software not started |
Green: solid | Synergis Cloud Link software started | ||
Green: 2 blinks per second | Connecting to Access Manager | ||
Green: 5 blinks per second | Firmware upgrade in progress Important: Do not
power cycle or power down the Synergis Cloud Link appliance while the
Information () LED is flashing green. Doing so might result in serious
damage to the unit. |
||
Orange: solid 3 seconds | DIP switch code recognized | ||
Red: 3 slow blinks | DIP switch code not recognized | ||
Red: blinking | Partial factory reset in progress | ||
Red: solid | Full factory reset in progress | ||
Green: blinking 1 second | Enable/disable IO Diagnostics page | ||
Power | Blue: solid | ON when 12 V dc or PoE power is applied | |
RS-485 | RX | Red: blinking | Receiving data |
TX | Green: blinking | Transmitting data | |
Ethernet ports | 1, 2 | Green | 1000BASE-T link is established. Flashes when there is activity. |
Yellow | 10BASE-T or 100BASE-TX link is established. Flashes when there is activity. | ||
PoE | Yellow: solid | ON if Synergis Cloud Link is being powered from a Power over Ethernet (PoE) source connected to Ethernet port 1. |